When most people test, they conveniently apply one lead to the ground, and look for voltage with the other lead. The results of this method will easily mislead you because even a neutral wire carries electricity when a component is running. There’s no reason not to expect to see voltage when tested in this fashion. If it is a 120 volt circuit, one lead must go to a neutral connection point, and the other to the point at which there should be 120 volts. A 240 volt test must include two separate points where individual 120 volt supply leads are providing power. Amperage Testing :  An amperage test can only be conducted when a component is actually running. The components that you might test with your ampmeter are the heater (120v should read amps, 240 volt should read 25 amps), the blower (1 Hp will read 5-6 amps, 1-1/2 to 2 Hp will read 7-9 amps), and the pumps low and high speeds (look at the plates on the motor for the amperages you should see and your actual reading should be within 10% of that). If your voltage supply to the pack is lower than the 120 volts or 240 volts as mentioned, then your amperage draw will be somewhat lower as well, (especially noticeable on heaters). On 120 volt tests, an amperage reading should only be taken on the lead actually supplying the voltage to a component (not on the neutral). For 240 volt components, either wire supplying power will give you a good reading.